Modular Walls for Cleanrooms

The flexibility of the Nicomac modular wall system for cleanrooms allows for easy installation and accepts on-site design modifications, enabling reconfiguration for different uses or relocation to other facilities.

Nicomac Mangini designs, manufactures, and installs self-supporting modular cleanroom wall panels, offering a wide range of materials, custom solutions, and personalized finishes. Thanks to the industrial strength of the Mangini Group, Nicomac’s modular panels for cleanrooms meet the demand for durability, safety, flexibility, reconfiguration, and reuse required by our clients.

MODULAR CLEANROOM WALL PANELS - DIMENSIONS. ASSEMBLY. SEAMS.

The standard dimensions of Nicomac modular cleanroom panels are: width 1,250 mm, overall height from 3 to 4.2 meters, and total thickness 45 mm. Additional wall heights can be achieved using a stacking technique. The self-supporting and insulated walls are assembled with an internal aluminum framework.

The seams of the modular cleanroom wall panels are silicone-sealed with a perfectly flush finish. The insulating materials are placed between the two outer skins and sealed externally by the aluminum framework. A selection of insulation materials and wall skins is available to meet various requirements in the construction of modular cleanrooms.

Nicomac_cleanroom_low_0069

Cleanroom Walls Types

Materials and solutions for every production need

image_grids_4_2
image_grids_4_2Glass
image_grids_4_2Metal
04

Cleanrooms Laminate Walls

High-pressure HPL laminate is the ideal material for cleanroom wall and ceiling panels. Nicomac’s HPL modular cleanroom walls are made of two layers of high-pressure plastic laminate, composed of cellulose fiber sheets impregnated with resin and subjected to a high-pressure process. This process, which involves the simultaneous application of heat and pressure, causes the resins to fluidize and polycondense, resulting in a homogeneous, scratch-resistant, non-porous, antibacterial material that can be modified for flush integration with any accessory. The panel is fully sealed with an aluminum frame.

Key Strengths

Scratch-Resistant Material for cleanrooms, offering high resistance to surface wear.

Built-in Air Recirculation System in the Wall.

Even when severely damaged, the core of the HPL layer is the same material that has been tested for resistance to highly aggressive cleaners, disinfectants, and sterilizers (such as Steris Sporklenz).

It is possible to integrate any accessory flush with the surface.

The unique material makes it easy to cut the panel and modify it on-site during wall installation.

Resistance to highly aggressive cleaners and disinfectants. Easy to clean.

5-year warranty: the high scratch resistance will keep your cleanroom looking great even after years of installation.

Cleanroom Glass Walls

02_GLASS-A

Full visibility of cleanroom areas provided by modular cleanroom glass walls is an increasingly common requirement in international standards. By reducing the need for access inside the cleanrooms, Nicomac glass wall systems minimize contamination sources linked to the operators themselves. At the same time, these solutions improve the work environment by increasing brightness, thereby promoting greater focus in managing operations in areas with fully glass walls.

Nicomac glass walls for cleanrooms can be supplied in any required size. With our MI 8009A001281 patent, the glass can be easily installed and removed for equipment integration without the need to remove ceiling and floor profiles. In the pharmaceutical sector, FDA inspectors positively view glass walls as they allow inspections of cleanroom system areas without the need to enter, thus avoiding any contamination risk.

For secondary areas, Nicomac has developed an open-space cleanroom partition wall, partially or fully glazed, with dedicated rounded aluminum profiles.

A true modular system for cleanrooms.

They allow full visibility and access to natural light.

Cleanroom system with an appealing design.

Easy supervision of operations in the cleanroom area.

03_METAL-B

Metal Cleanroom Wall Panels

Nicomac Mangini manufactures and installs cleanroom wall panels made of galvanized steel, powder-coated with a thickness of 0.8 mm, covered with 100µ PVC to ensure high mechanical protection.

High mechanical resistance due to the increased thickness and PVC coating.

Panels available in thicknesses of 45 mm – 82 mm, with built-in air intakes.

Resistance to low humidity and high fluctuations in ambient humidity.

Liquid uPVC sealing is available as an alternative to silicone.

Resistant to highly aggressive cleaners and disinfectants. Easy to clean.

5-year warranty.

Download the Catalogue

CLEANROOM MODULARI

Discover Nicomac’s detailed solutions for cleanroom systems in the pharmaceutical, nutraceutical, and life science sectors.

CATALOGUE

NICOMAC MODULAR CLEANROOM

Screenshot CATALOGUE

Want to learn more?

Get an rapid feedback to your questions!
Fill out the form to receive a quick and targeted response. Whether you're looking for detailed information, a customized quote, or proposing a collaboration, the Nicomac team will review your request and get back to you as soon as possible.

    NICOMAC-logo-bianco

    PART OF MANGINI GROUP

    SOCIAL

    Mangini-Healthcare
    Mangini-Workspace
    Mangini-Lighting
    Mangini-Hospitality
    Mangini-Technical-Doors
    LogoACOTEC
    Mangini-NICOS
    Mangini-Helthcare-colore
    Mangini-Workspace-colore
    Mangini-Lighting-colore
    Mangini-Hospitality-colore
    Mangini-Doors-colore
    Acotec-colore
    Nicos-usa-colore

    Copyright © 2025 - Nicomac Srl All Rights Reserved
    P.I./C.F.: 07434210964 - SDI: BA6ET11
    PEC: nicomacsrl@pec.nicomac.it


    Privacy

    Preferences

    Cookies